title: "Philips Clinical Collaboration Platform vulnerabilities and CVEs"
url: https://radicalnotion.ai/vendor/philips/clinical-collaboration-platform
type: product
description: "Philips Clinical Collaboration Platform has 8 published CVEs, 0 in CISA KEV and 0 with public exploits."
updated: 2025-06-02
source: RadicalNotion.AI
license: CC BY-NC 4.0 (https://creativecommons.org/licenses/by-nc/4.0/)
---

# Philips Clinical Collaboration Platform vulnerabilities

Vendor: [Philips](https://radicalnotion.ai/vendor/philips)

- **Published CVEs:** 8
- **In CISA KEV:** 0
- **With a public exploit:** 0
- **With a patch:** 5
- **Average CVSS:** 5.9
- **First CVE:** 2020-09-18
- **Latest CVE:** 2025-06-02

## Severity breakdown

| Severity | CVEs |
| --- | --- |
| Critical | 0 |
| High | 1 |
| Medium | 6 |
| Low | 1 |
| Unscored | 0 |

## Most common weakness types

| CWE | Name | CVEs |
| --- | --- | --- |
| [CWE-77](https://radicalnotion.ai/cwe/cwe-77) | Improper Neutralization of Special Elements used in a Command ('Command Injection') | 2 |
| [CWE-16](https://radicalnotion.ai/cwe/cwe-16) | Configuration | 1 |
| [CWE-352](https://radicalnotion.ai/cwe/cwe-352) | Cross-Site Request Forgery (CSRF) | 1 |
| [CWE-1259](https://radicalnotion.ai/cwe/cwe-1259) | Improper Restriction of Security Token Assignment | 1 |
| [CWE-757](https://radicalnotion.ai/cwe/cwe-757) | Selection of Less-Secure Algorithm During Negotiation ('Algorithm Downgrade') | 1 |
| [CWE-83](https://radicalnotion.ai/cwe/cwe-83) | Improper Neutralization of Script in Attributes in a Web Page | 1 |
| [CWE-693](https://radicalnotion.ai/cwe/cwe-693) | Protection Mechanism Failure | 1 |

## CVEs by year

| Year | CVEs published |
| --- | --- |
| 2020 | 5 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 3 |

## Affected versions

| Version | Kind | CVEs |
| --- | --- | --- |
| \< 12.2.1 | range | 5 |
| \<= 12.2.1 | range | 5 |
| 12.2.1.5 | range | 3 |
| 12.2.1 | patched | 5 |

## CVEs

| CVE | Title | Severity | CVSS | CISA KEV | Public exploit | Patch |
| --- | --- | --- | --- | --- | --- | --- |
| CVE-2025-27955 | - | medium | 6.5 | No | No | No |
| CVE-2025-27954 | - | medium | 6.5 | No | No | No |
| CVE-2025-27953 | - | medium | 6.5 | No | No | No |
| CVE-2020-16247 | Philips Clinical Collaboration Platform Configuration | high | 7.1 | No | No | Yes |
| CVE-2020-16200 | Philips Clinical Collaboration Platform Algorithm Downgrade | medium | 6.5 | No | No | Yes |
| CVE-2020-16198 | Philips Clinical Collaboration Platform Protection Mechanism Failure | medium | 6.3 | No | No | Yes |
| CVE-2020-14525 | Philips Clinical Collaboration Platform Improper Neutralization of Script in Attributes in a Web Page | low | 3.5 | No | No | Yes |
| CVE-2020-14506 | Philips Clinical Collaboration Platform Cross-site Request Forgery | medium | 4.3 | No | No | Yes |

## Frequently asked questions

### How many CVEs does Philips Clinical Collaboration Platform have?

Philips Clinical Collaboration Platform has 8 published CVE records since 2020.

### How many Philips Clinical Collaboration Platform CVEs are in CISA KEV?

None of Philips Clinical Collaboration Platform's CVEs are currently listed in CISA's Known Exploited Vulnerabilities catalog.

### Are there public exploits for Philips Clinical Collaboration Platform vulnerabilities?

No Philips Clinical Collaboration Platform CVEs currently have a tracked public exploit in this dataset.

### Which versions of Philips Clinical Collaboration Platform are affected?

4 distinct Philips Clinical Collaboration Platform versions are named across its CVEs. Use the version filter above to see the CVEs affecting a specific version.

### What are the most common weakness types in Philips Clinical Collaboration Platform CVEs?

Philips Clinical Collaboration Platform's CVEs most often map to these CWE weakness types: CWE-77 (Improper Neutralization of Special Elements used in a Command ('Command Injection')), CWE-16 (Configuration), CWE-352 (Cross-Site Request Forgery (CSRF)), CWE-1259 (Improper Restriction of Security Token Assignment).

### What is the average severity of Philips Clinical Collaboration Platform CVEs?

The average CVSS base score across Philips Clinical Collaboration Platform's scored CVEs is 5.9.

## Other products from this vendor

- [IntelliSpace Portal](https://radicalnotion.ai/vendor/philips/intellispace-portal) (14 CVEs)
- [patient information center ix](https://radicalnotion.ai/vendor/philips/patient-information-center-ix) (11 CVEs)
- [e-alert firmware](https://radicalnotion.ai/vendor/philips/e-alert-firmware) (10 CVEs)
- [e-Alert Unit (non-medical device)](https://radicalnotion.ai/vendor/philips/e-alert-unit-non-medical-device) (9 CVEs)
- [hue bridge v2](https://radicalnotion.ai/vendor/philips/hue-bridge-v2) (9 CVEs)
- [hue bridge v2 firmware](https://radicalnotion.ai/vendor/philips/hue-bridge-v2-firmware) (9 CVEs)
- [Philips IntelliSpace Portal](https://radicalnotion.ai/vendor/philips/philips-intellispace-portal) (9 CVEs)
- [Vue PACS](https://radicalnotion.ai/vendor/philips/vue-pacs) (9 CVEs)

---

Source: [RadicalNotion.AI](https://radicalnotion.ai/vendor/philips/clinical-collaboration-platform). Licensed CC BY-NC 4.0; attribute RadicalNotion.AI and link the source page when you reuse this data.